Wire Harnesses & Cable Assemblies

Harnesses built to drawing: wire gauge, connector to connector mapping, sleeving and labelling quoted as one assembly.

A harness is a drawing, a connector list and a test

A harness quote is only as good as its documentation. The same assembly described as "cable with two connectors" can be built in ways that differ in wire gauge, shielding, strain relief and whether the shield is tied at one end or both — and each of those changes the failure mode in the field.

We quote from a drawing plus a connector list: which connector at each end, wire gauge and colour, length with tolerance, sleeving or braid, labelling and the test the assembly must pass. Where the drawing is incomplete we propose the missing details and mark them for approval, because an unstated detail becomes a defect the day it matters.

For pilot builds we quote assemblies with a continuity and hi-pot test per unit. It costs a little per harness and removes the most common cause of a first-article rejection.

Typical specifications

Parameter Sourcing range
Wire gauge AWG 16 – AWG 28 (drawing dependent)
Connector ends One or both ends, from the interconnect cluster
Length tolerance Quoted per drawing, typically ±5 mm
Protection Sleeving, braid, heat-shrink, strain relief
Test Continuity and hi-pot per unit on request
Labelling Per drawing, including heat-shrink markers
Sourcing note · Made to drawing: quoted per project with connectors, test and lead time included.

Where it is used

Machine internal wiring between boards
Motor and encoder leads
Panel-to-board connections
Field-replaceable cable sets

FAQ

Can you build from a sample instead of a drawing?

A sample can be copied, but a drawing should be produced alongside it, because the copy inherits whatever the sample happened to be rather than what the design needs. We quote both steps.

Do you supply the connectors?

Yes, from the interconnect cluster, so the harness is quoted with the parts it is built from and the mating interface is verified.

How is quality checked?

Continuity and hi-pot per unit on request, with the test record shipped alongside. For safety-related harnesses we recommend this on every unit rather than by sampling.

Ready to Source Components?

Contact us today for competitive pricing and fast delivery worldwide.